NexComm N560 (EoC) Simple Setup Configuration



Here is a simple way on how to configure a two N560 model.

 Know the 2Base-TL Pin Assignment (RJ45 connector)
o   Line #1 – Blue/White-Blue
o   Line #2 – Brown/White-Brown
o   Line #3 – Green/White-Green
o   Line #4 – Orange/White-Orange

·         Configure the Laptop or Desktop to access modem
o   IP Address: 172.16.0.56
o   Subnet Mask: 255.255.255.0
o   Gateway: 172.16.0.55
·         Access N650 via Telnet or Serial Port
o   For telnet;
§  Run command “telnet 172.16.0.55”
o   For Serial Port ,
§  Data rate : 38400
§  Data bits : 8
§  Stop bits : 1
§  Parity : None
§  Flow Control : None
·         Default User access
o   Username : admin
o   Password : password
o   Enable password : password
·         Modem #1 Config
o   N560>(enable) set system time {time}
o   N560>(enable) set system hostname {hostname}
o   hostname >(enable) set devicetype co
o   hostname >(enable) set devicemode binding
o   hostname >(enable) set vlmode transparent
o   hostname >(enable) restart pme all
o   hostname >(enable) write config0
·         Modem #2 Config
o   N560>(enable) set system time {time}
o   N560>(enable) set system hostname {hostname}
o   hostname >(enable) set devicetype rt
o   hostname >(enable) set devicemode binding
o   hostname >(enable) set vlmode transparent
o   hostname >(enable) restart pme all
o   hostname >(enable) write config0